Area velocity flow meter

MSFM S2.5T

The area velocity flow meter our fleet runs on: battery powered, certified for Zone 0 and built for raw sewage.

MSFM S2.5T
Area velocityVelocity 0.03 to 4 m/s, depth to 3.5 m
Water temperature0 to 50 °C, a clue to infiltration
Flow on boardAnd a pulse to run a sampler
4G LTELogs every 1 to 60 minutes
15+ weeks a chargeAt 2-minute logging
Zone 0ATEX and IECEx certified

The MSFM S2.5T is a self-contained, battery-powered flow meter for raw sewage, industrial effluent and stormwater. It works in combined sewers, storm sewers and open channels, with no weir or flume.

One sensor at the bottom of the pipe measures velocity, depth and water temperature. The meter works out the flow, logs every 1 to 60 minutes and sends its readings over 4G LTE.

It’s the meter our sewer flow fleet runs on, so the advice comes from the people who install it. Buy it, hire it, or have us run it for you.

Three readings, one sensorVelocity from dual piezoelectric elements, depth from hydrostatic pressure, and water temperature, which also corrects the other two.
Flow worked out on boardA second processor calculates flow from depth, velocity and the shape of the pipe or channel.
Samples in proportion to flowEach time a set volume has passed, it sends a pulse to an automatic sampler.
Temperature finds infiltrationGroundwater or tidal water getting into a sewer changes its temperature as well as its flow.
A second depth, if you want oneAdd a LIDoTT ultrasonic level sensor and depth is measured two ways, each logged on its own channel.
Built for the manholeSealed to IP68 with Mil-spec connectors, in a protection frame that fixes to the step irons.

High in the shaft, low in the pipe.

  • The meter hangs high in the shaft, on the step irons or a fixing spike
  • Its sensor sits on a stainless ring at the bottom of the pipe, facing into the flow
  • One sensor measures velocity, depth and water temperature
  • Flow is worked out in the meter and logged every 1 to 60 minutes
  • Readings go out over 4G LTE, as often as every 15 minutes
Illustration: the MSFM S2.5T high in the manhole, its sensor on a ring at the bottom of the pipe. Not to scale.

How it goes in

Good data starts with the right spot in the pipe and a careful install.

  • Sited away from bends and side inlets, where the flow runs straight
  • In a round pipe, the sensor rides a stainless ring locked inside the pipe, with a scissor expander in larger pipes
  • In a rectangular channel, it sits on a bracket about a third of the way across
  • The cables are tied along the ring and taped smooth, so rag has nothing to catch on
  • Once it’s in, the readings are checked against a reference velocity meter and a dip with a ruler
An MSFM area velocity sensor on its band at the bottom of an incoming sewer line, its yellow cable running out through the flow
An MSFM sensor installed by EDS at the bottom of an incoming line, measuring depth and velocity.

Where it works.

Sewer Flow Surveys

Short I&I studies and long-term programs in gravity sewers.

Inflow and Infiltration

Flow and water temperature together show where water gets in.

Combined Sewer Overflows

Flow in the sewer, with an ultrasonic level sensor at the overflow.

Trade Waste and Sampling

A pulse to a sampler each time a set volume has passed.

Common Questions

Do I need a weir or flume?

No. The MSFM S2.5T measures velocity and depth in the pipe or channel as it is, and keeps up as storms or production change the flow.

What pipes and channels does it suit?

Round pipes, and rectangular and trapezoidal channels. The meter works out the flow from its depth, velocity and the size you enter. For other shapes, ask us.

How long does the battery last?

The sensors run off a 12 V rechargeable lithium-ion pack: more than 15 weeks at 2-minute logging, or 30 weeks or more at 5-minute logging. The pack’s voltage is logged, so a swap can be planned before it runs low, and it changes on site with an Allen key. The logger has its own internal battery, with a typical life of five years.

Can it run a sampler?

Yes. It works out the flow on board and sends a pulse to an automatic sampler each time a set volume has passed, for flow-proportional sampling. In a hazardous area, the sampler must be certified too.

Where does the data go?

On an EDS program, the readings arrive in EDS FlowSense. The meter can also report to Detectronic’s own DetecData portal. It sends every 15 minutes, hourly, daily, weekly or monthly.

Can I hire one?

Yes. The MSFM S2.5T is in our hire fleet for temporary flow surveys. Or take Data as a Service: we choose the sites, install and maintain the meters, and deliver validated data.

Specifications

MSFM S2.5T in detail.

Velocity

TypeDual piezoelectric elements
Range0.03 to 4.00 m/s
Resolution1 mm/s
Linearity± 1 %
Accuracy± 2.5 % FS; ± 1 % in the calibrated range, 0.05 to 2.00 m/s

Depth

TypeHydrostatic pressure
Range0 to 3.5 m
Resolution1 mm
Linearity0.1 % BSL
Accuracy± 0.2 % FS; ± 0.1 % in the calibrated range, 0.03 to 2.00 m

Temperature

TypeCurrent derived resistance bridge
Range0 to 50 °C
Accuracy± 1 °C

Optional LIDoTT Level

TypePiezo-ceramic ultrasonic, temperature compensated
Range0 to 1.5 m
Accuracy± 2 mm

Logging and Communications

Logging interval1 to 60 minutes
Memory512k solid state, up to 60k per channel
StorageRotating, or until full
Network4G LTE (LTE-M and NB-IoT)
ReportingEvery 15 minutes, hourly, daily, weekly or monthly
Flow calculationOn board: circular, rectangular or trapezoidal channels
Pulse outputFlow proportional, for an automatic sampler

Power

Sensor battery12 V ATEX lithium-ion pack, rechargeable
Battery life30+ weeks at 5-minute logging; 15+ weeks at 2-minute
Battery pack life5 years typical
Logger batteryInternal lithium pack, user replaceable, 5 years typical

Enclosure and Environment

Operating temperature−20 to 60 °C
ProtectionIP68 / NEMA 6P
ConnectorsIP68 Mil-spec
Dimensions530 × 213 × 150 mm maximum, with battery pack and frame
Weight8.5 kg with battery pack, frame and sensors on 10 m cables

ApprovalsEx hazardous area markIECEx

ATEXSira 19ATEX2255X
MarkingII 1G Ex ia IIB T4 Ga, Ta −40 to 60 °C
IECExIECEx SIR 19.0078X

Figures from Detectronic’s datasheet. Battery life depends on the logging and reporting intervals. Full details are in the MSFM S2.5T datasheet.

Put an MSFM in your sewer.

Buy it, hire it, or have our crews run it for you. Tell us about your sites and we’ll come back with pricing and a plan.

How can we help?

Prefer to talk? Call 1300 721 683, or find our offices.