Sensor mount for gravity sewers

Sensor Fort

How to install pH, EC and other water quality sensors in a gravity sewer, and keep them working. The only mount that hides everything but the sensor tip.

Patent-pending design

Sensor Fort
Sensor Fort in a 150 mm sewer, with the pipe cut away. The design is patent pending.
Only the tips meet the flowSensor bodies, clamps and cables stay inside the mount
Nothing for rag to catchA smooth saddle that flow and rag can only pass over
Works with 99% of sensorsOn the market, as tested by EDS, from any maker
150 to 1050 mm sewersOne Sensor Fort for each pipe diameter
Runs on nothing but your sensorsNo power, no pump and no moving parts to look after
Flow from the same siteThe spill lip is a hydraulic control, so depth gives flow

Installing a pH, EC or dissolved oxygen sensor in a gravity sewer is hard, and the hard part isn’t the sensor. It’s how you hold it in the flow. Rag wraps around anything that divides the flow, grit buries whatever sits in slow water, fat coats whatever sits at the waterline, and low flows leave sensors dry.

Sensor Fort is a low moulded saddle that sits on the bottom of the pipe (the invert) at a manhole. Two sensors lie inside it, pointing downstream. The flow rides up the saddle, spills over a lip and runs fast across their tips. Nothing else is exposed.

EDS designed Sensor Fort and builds it in Australia, drawing on more than 30 years of experience and knowledge of sewers, to solve that one problem. It needs nothing to run except your sensors: no power, no pump and no moving parts. It works with 99% of the sensors on the market, as tested by EDS, so you keep the ones your network already trusts. And it’s designed to stay in the sewer for 12 months between visits. The design is patent pending.

One body. Two protected bays.

12345678
  1. Feathered nose
  2. Cable hood
  3. Shoulder over a sensor bay
  4. Valley
  5. Cable clamp
  6. Spill lip
  7. Stern face
  8. Sensor tips
The sensors lie under the shoulders and show only their tips at the stern. Each cable leaves under a hood on its shoulder. The design is patent pending.

Four ways to hold a sensor in a sewer.
None of them works, and none ever will.

In a gravity sewer the weak point is the mount, not the sensor. Rag wraps around anything that divides the flow. Grit buries whatever sits in slow water. Fat coats whatever sits at the waterline. And low flows leave sensors dry. Each of these fails for a mechanical reason that no sensor can overcome.

What doesn’t work

  1. Needs regular cleaning

    Pole, chain or pendulum from above

    Rag catches where the pole pierces the surface, and on the sensor itself. A ring of fat forms at the waterline.

  2. The best of the four, and it still rags

    Sensor strapped to a band

    Rag catches on the sensor body, the clamps and the cable. Silt settles in the lee of the sensor.

  3. Unreliable in a sewer

    Float on a tether

    Rag collects on the float and its tether. At low flow the float grounds or tips over.

  4. Needs a pump, power and visits

    Pumped bypass to a flow cell

    The intake blocks, and the tubing and the flow cell foul between visits.

What does

Sensor Fort seen from downstream inside a pipe: two shoulders against the pipe wall, an open valley between them, and two sensor tips side by side at the bottom
From downstream. The centre of the sewer stays open above the valley.

The idea

Hide everything but the tip.

So we changed the mount, drawing on more than 30 years of working in sewers. Sensor Fort gives rag nothing to wrap around, keeps every cable out of the flow and leaves no sensor body to be buried. No other mount does all three, which makes it the only solution for analytical sensors in a gravity sewer network.

Patent-pending design

  • RagNo leading edge. The saddle spans the invert, so flow and rag can only pass over it.
  • GritThe tips sit just below the spill lip, where fast water keeps grit moving.
  • Low flowEach sensor lies 15° tip down, so its tip is the last part to go dry.
  • UpkeepIt needs nothing to run except your sensors: no pump, no power and no moving parts. Designed for 12 months between visits.

Shaped so the flow keeps the tips clear.

Sensor Fort works by shape alone. The flow rides up a feathered nose, gathers in the valley between two shoulders, spills over a lip and runs fast across the sensor tips. The same shape keeps every sensor body, clamp and cable out of the stream.

81 mm36 mmflow150 mm sewer123456Deep and slow in the poolShallow and fast across the tips
  1. Feathered nose
  2. Cable hood, clear of the stream
  3. Valley for low flows
  4. Sensor inside the shoulder
  5. Spill lip
  6. Sensor tips in fast water
Section along the centre line of the SF 150 in a 150 mm sewer. The water levels at each end were calculated for 1.9 L/s at a grade of 1%. The surface between them is schematic, and the pale area is the thin skin against the pipe wall. The moving water is an illustration: it runs faster where it is shallower, and the brown strands are rag passing over.

Six design rules

  1. Rule 1No leading edge

    Rag catches where flow divides around an edge. The saddle spans the invert, so flow can only pass over it.

  2. Rule 2Only the tips are exposed

    Sensor bodies, clamps and cables stay inside. The flow side has no seam, hole or fastener.

  3. Rule 3Tips at the lowest point

    Each sensor lies 15° tip down, so its tip is the last part of the installation to go dry.

  4. Rule 4Tips in the fastest water

    The tips sit just below the spill lip, where fast water keeps biofilm thin and grit moving.

  5. Rule 5No cable in the flow

    Each cable leaves its bay under a hood and runs to the top of the pipe in a covered channel.

  6. Rule 6Low and full width

    A low hump that fills the invert sheds debris over its top, where a post would hold it.

What no mount can do. No mount can stop biofilm growing or a pH reference ageing, though fast water keeps biofilm thin. So we match the sensor type and the data checks to the service interval each site needs.

Flow and water quality from one site.

The spill lip is a hydraulic control, like a flume or weir, so the depth upstream rises predictably with flow. Fit Sensor Fort in the outlet pipe of a manhole and it holds a pool in the channel across the manhole floor (the chase). A level sensor above the chase, or a pressure sensor in it, measures the depth. We turn that depth into flow with a rating curve for the mount, while the sensors keep measuring water quality.

113 mmflowManhole375 mm sewer123456
  1. Sensor Fort in the outlet pipe
  2. Spill lip, the hydraulic control
  3. Sensor tips
  4. Pool held in the chase
  5. Level sensor above the chase
  6. Or a pressure sensor in the chase
Sensor Fort in the outlet pipe of a manhole on a 375 mm sewer, with a level sensor above the chase. The depth shown was calculated for the SF 375 at 10 L/s and a grade of 0.5%. The figure is schematic.

Calculated rating, SF 375 in a 375 mm sewer

The depth held in the chase at each flow.

  1. Depth in the chase 62 mmFlow 1 L/s
  2. Depth in the chase 71 mmFlow 2 L/s
  3. Depth in the chase 90 mmFlow 5 L/s
  4. Depth in the chase 113 mmFlow 10 L/s
  5. Depth in the chase 145 mmFlow 20 L/s
  6. Depth in the chase 193 mmFlow 40 L/s

The rating applies while the flow over the lip is free. At flat grades the lip can drown at high flows, and the rating then no longer applies.

  • One site, one entry

    Flow and water quality are measured, logged and reported together from one installation.

  • Loads and context

    Flow puts every reading in context, and lets you work out loads as well as concentrations.

  • No assumed roughness

    A rating at a control doesn’t depend on an assumed pipe roughness or grade, as an estimate from Manning’s equation does.

  • Confidence in the data

    The depth record shows when the sensor tips are covered and when the sewer runs dry.

Your sensors. Your sewer.

Sensor Fort works with 99% of the sensors on the market, as tested by EDS. We surveyed 48 pH, conductivity and dissolved oxygen sensor models from 22 makers, and sized the sensor bays to suit them. The larger the sewer, the larger the sensor its Sensor Fort takes. A sleeve adapts each sensor to its bay, so you fit your own sensors, certified for your own zones.

ModelPipe diameterLargest sensor bodyTypical sensor formatsSurveyed models that fit
SF 150, SF 225150 and 225 mm28.5 mm by 190 mm12 mm electrodes in a sleeve, compact 22 mm sensors and 3/4 inch NPT bodies54%26 of 48
SF 300, SF 375300 and 375 mm35.5 mm by 270 mmIn addition, 1 inch NPT bodies and 35 mm differential sensors75%36 of 48
SF 450 to SF 1050450 to 1050 mm51 mm by 315 mmIn addition, 1.5 inch NPT bodies, 51 mm differential sensors and optical oxygen sensors96%46 of 48
To order525 mm and larger80 mm by 600 mmMultiparameter sondes and long armatures100%48 of 48
1502253003754505256007509001050
One Sensor Fort for each pipe diameter, in millimetres. Schematic end views, with the diameter, lip height and shoulder height drawn to scale. Sizes between those shown are made to order.
  • A 12 mm electrode fits every Sensor Fort

    pH, ORP, conductivity and dissolved oxygen sensors all come as 12 mm electrodes, so there’s a sensor for every sewer.

  • Conductivity

    In sewers smaller than 450 mm, use a four-electrode conductivity sensor. Inductive heads fit the SF 450 and larger by size, but need a site check, because the whole head must stand in the flow.

  • Check the fit first

    The survey was done in November 2026. Please confirm the fit of your sensor with us before you order.

One screw fastens both sensors.

The sensors lie in two straight bays under the shoulders, 15° tip down. Each bay opens only towards the pipe wall, so the side that faces the flow is one continuous skin.

1234
The open side of a bay, with the clamp bar and its screw drawn clear. The numbers match the steps.
  1. Sleeve the sensor

    A 12 mm electrode screws into its sleeve by its PG13.5 thread. A larger body takes a split sleeve.

  2. Lay it in the open bay

    Turn the mount over on the bench, lay the sensor in and slide it downstream until its sleeve meets the stern ring.

  3. Tighten one screw

    A single clamp bar beneath the stern presses both sleeves home, so one M5 screw fastens both sensors.

  4. Clamp the cable

    A small clamp holds each cable in its groove, so a pull on the cable never reaches the sensor.

  • No fastener faces the flow

    The clamp bar sits in a pocket beneath the stern.

  • The pipe wall closes the bays

    Each bay opens only towards the pipe wall, which leaves the flow side seamless.

  • A solid stop for every sensor

    Each sleeve bears on the stern ring, so drag and the 15° tilt both press the sensor home.

Load it on the bench. Leave it for 12 months. Swap it.

The work happens on the bench, not in the manhole. A loaded mount goes into the pipe on an EDS expansion band, and at the next visit the whole mount is exchanged for a fresh one.

  1. Load

    Each sensor is sleeved, clamped in its bay, calibrated and capped wet on the bench.

  2. Install

    The loaded mount is fixed on its EDS expansion band in the pipe, with nothing drilled.

  3. Leave

    The mount is designed to stay in the sewer for 12 months between visits.

  4. Swap

    The whole mount is exchanged for a freshly loaded one, and the old one is refurbished.

Supplied as part of an EDS monitoring solution

  • Complete sites

    We supply Sensor Fort with the Metalog 4G logger, an upstream level sensor where you need flow, and commissioning into FlowSense.

  • Your sensors

    Use the sensors your network already trusts. We supply the mount and the sleeves, and match the data checks to the service interval.

  • Your own system

    The mount has no electrical parts, so sensors with 4 to 20 mA or Modbus outputs connect to any RTU, logger or SCADA host.

One Sensor Fort for each pipe diameter.

Each one forms a low hump in the sewer. Check upstream connections and overflow levels against these figures before you choose a site.

ModelPipe diameterLargest sensor bodyLip heightLengthArea occupiedTips covered aboveRise at a grade of
0.1%0.5%1%
SF 150150 mm28.5 mm4031426%0.4 L/sNot calculated4159
SF 225225 mm28.5 mm3932012%0.4 L/sNot calculated3660
SF 300300 mm35.5 mm4642610%2.5 L/sNot calculated4578
SF 375375 mm35.5 mm454337%2.5 L/sNot calculated4788
SF 450450 mm51 mm625319%5.5 L/s5367120
SF 525525 mm51 mm615407%5.5 L/s5271Not calculated
SF 600600 mm51 mm615736%6 L/s5275Not calculated
SF 750750 mm51 mm616394%6.5 L/s5184Not calculated
SF 900900 mm51 mm606863%8 L/s5095Not calculated
SF 10501050 mm51 mm607212%8.5 L/s49107Not calculated

Dimensions and rises are in millimetres, and each model holds two sensors. Lip height is from the invert to the spill lip. Area occupied is the share of the pipe area the mount takes up at its widest section. Tips covered above is the calculated flow above which the sensor tips are fully under water. Rise is the largest calculated rise in the upstream water level over the flow range; a dash falls outside the grades calculated for that model. Sensor Forts for sondes up to 80 mm are made to order for sewers of 525 mm and larger, as are sizes between those listed.

Before you choose a site

  • Upstream level

    Check upstream connections and overflow levels against the rise in the table.

  • Capacity

    Avoid sewers that surcharge in dry weather, because the pipe upstream of the mount runs full first.

  • Steep sewers

    Above a grade of about 0.7% the flow is supercritical, and a hydraulic jump forms upstream of the mount.

  • Low flow

    Below the flow in the table the sensor tips are partly exposed, and at zero flow they drain. Choose a sewer with a continuous base flow.

  • Sediment

    Solids can settle in the upstream pool in dry weather, but the tips sit downstream of the lip, clear of the deposit.

  • Cleaning and CCTV

    A jetting nozzle or camera crawler can’t pass the mount, so agree a removal procedure with the asset owner.

Where it works.

Trade waste

pH and conductivity at a discharge point or in the receiving sewer.

Source tracking

Paired sites that narrow down where an abnormal discharge enters the network.

Saline ingress

Conductivity changes that reveal saline water entering the network.

Odour control

pH and dissolved oxygen trends that support septicity and dosing studies.

Installing pH, EC and water quality sensors in a sewer.

Short answers. The detail is above, and in the datasheet.

How do you install a pH or EC sensor in a sewer?

Mount it where rag can’t catch it. Sensor Fort is a low saddle that sits on the invert of the pipe at a manhole, fixed on an expansion band with nothing drilled. The sensor lies inside it, 15° tip down, with only its tip in the flow. Each sensor is sleeved, calibrated and capped wet on the bench first, and the loaded mount then goes into the pipe.

Why do water quality sensors foul in a sewer?

Usually because of the mount, not the sensor. Rag wraps around anything that divides the flow, grit buries whatever sits in slow water, fat coats whatever sits at the waterline, and low flows leave sensors dry. Poles, bands, floats and pumped bypasses each fail for one of those reasons.

Which water quality sensors can be installed in a sewer with Sensor Fort?

Sensor Fort works with 99% of the sensors on the market, as tested by EDS. It takes any cylindrical sensor that measures at its tip, from any maker, including pH, ORP, conductivity (EC) and dissolved oxygen. A sleeve adapts each sensor to its bay, from 12 mm electrodes to 80 mm sondes in larger sewers. Each mount holds two sensors.

What size sewer does it suit?

Gravity sewers from 150 mm to 1050 mm in diameter, with one Sensor Fort for each pipe diameter. It is made for circular pipe, with U-shaped channels on request. Choose a sewer with a continuous base flow, so the sensor tips stay wet.

How often do sensors in a sewer need servicing?

Sensor Fort is designed to stay in the sewer for 12 months between visits. The whole mount is then exchanged for a freshly loaded one. No mount can stop biofilm growing or a pH reference ageing, so we match the sensor type and the data checks to the service interval each site needs.

Does it need power or a pump?

No. Sensor Fort needs nothing to run except your sensors. It is passive, with no moving parts, no electrical parts and no power. Sensors with 4 to 20 mA or Modbus outputs connect to any RTU, logger or SCADA host, or to an EDS Metalog 4G logger.

Can I measure flow at the same site?

Yes. The spill lip is a hydraulic control, so the depth upstream rises predictably with flow. With Sensor Fort in the outlet pipe of a manhole, a level sensor above the chase measures that depth, and a rating curve for the mount turns it into flow.

Who makes Sensor Fort?

EDS (Environmental Data Services) designed Sensor Fort and builds it in Australia, drawing on more than 30 years of experience in sewer monitoring.

Is Sensor Fort patented?

The Sensor Fort design is patent pending. EDS designed it and builds it in Australia.

Specifications

Sensor Fort in detail.

The SF 150, for a 150 mm sewer, in millimetres: plan, section on the centre line and the view from downstream. The other models are in the range table.

General

ProductSensor Fort (SF), passive sensor mount
OriginDesigned and built in Australia by EDS
FunctionHolds one or two analytical sensors on the invert, with only their tips in the flow
Pipe diameters150 mm to 1050 mm, with one model for each pipe diameter
Pipe shapeCircular pipe; U-shaped channels on request
OperationPassive, with no moving parts, no electrical parts and no power
ProtectionPatent pending on the design

Sensor bays

NumberTwo bays; a blanking plug closes an unused bay
Sensor sizeBodies to 28.5 mm in SF 150 and SF 225, 35.5 mm in SF 300 and SF 375, and 51 mm from SF 450
AttitudeSensors lie 15° tip down, with their tips pointing downstream
Tip exposureFlat tips sit flush with the stern; a 12 mm electrode stands 20 mm proud
Sensor typesAny cylindrical sensor that measures at its tip, including pH, ORP, conductivity and dissolved oxygen
Bay sealingThe bays flood in service; use plugs rated for immersion or a removable sealing gel

Fastening

SleeveOne for each sensor family; sets the tip at the stern
Clamp barOne bar beneath the stern and one M5 × 16 socket head cap screw fasten both sleeves
Cable clampOne for each cable, with one M4 × 12 screw; takes any pull on the cable

Sleeves and parts, SF 150 and SF 225

12 mm electrodeThreaded sleeve for electrodes 120 mm long with a PG13.5 thread; leaves 20 mm of the tip in the flow
22 to 26.7 mmSplit sleeves for 22.0, 22.9, 25.4, 26.0 and 26.7 mm bodies; the 26.7 mm sleeve also suits 3/4 inch NPT threads
28 to 28.5 mmShims, as these bodies pass the stern ring bare
Tail ring, plugA tail ring centres the rear of a slim body, and a blanking plug closes an unused bay
Plug headAllow up to 24 mm in diameter for the plug head and cable coupling
Larger modelsSleeves are supplied to suit the sensors ordered

Service

ConceptSensors are loaded and calibrated on the bench, and the whole mount is exchanged
IntervalDesigned for 12 months between visits
Sensor careNo mount can prevent biofilm growth or reference ageing, so sensor choice and data checks still apply

Materials

BodyMoulded polymer, in cast polyurethane or HDPE
Other partsEngineering polymer sleeves and clamps; 316 stainless steel band and fasteners
MassAbout 0.5 kg for the SF 150, without sensors
Classified zonesNo electrical parts; specify a static dissipative body grade. Sensors are certified by the client

Installation

PositionIncoming pipe of a manhole, or the outlet pipe where flow is also measured
FixingEDS expansion band, with nothing drilled
OrientationThin feathered nose upstream, sensor tips downstream
Cable routeBeneath a hood on each shoulder, then in a covered channel to the obvert
AccessConfined space entry, as for an EDS flow sensor
Cleaning, CCTVA jetting nozzle or camera crawler cannot pass; agree a removal procedure with the asset owner

Hydraulics, SF 375

Lip height45 mm, or 12% of the diameter
Area occupied7% of the pipe area at the widest section
Upstream riseUp to 40 mm at a grade of 0.25%, 47 mm at 0.5% and 88 mm at 1%
Tips coveredAbove about 2.5 L/s for a 35 mm sensor body

Flow indication

PrincipleThe spill lip acts as a hydraulic control, so upstream depth rises predictably with flow
MeasurementLevel sensor above the chase of the manhole, or a pressure sensor in it, with the mount in the outlet pipe
RatingCalculated rating curve for each model. SF 375: about 62 mm at 1 L/s, 113 mm at 10 L/s and 193 mm at 40 L/s
ConditionsFree flow over the lip; the rating does not apply once the lip is drowned

Dimensions, SF 150

Length314 mm
Width149 mm
Height114 mm at the cable hoods
Lip height40 mm above the invert
Sensor axis15° tip down
Bay diameter31.0 mm, stern ring 29.4 mm

Supplied by EDS

MountMade to the diameter of the sewer, with its clamp bar and cable clamps
Sensor partsSleeves, shims and plugs to suit your sensors
In the pipeThe EDS expansion band and the cable channel
ServiceBench loading, installation and the exchange service
Where requiredThe Metalog 4G logger, FlowSense and an upstream level sensor for flow

Ordering

Model codeSF followed by the pipe diameter in millimetres; for example, SF 375
PipeInternal diameter, material and condition
HydraulicsGrade, dry weather flow range and overnight depth
SensorsMake, model, body diameter and length, thread and plug head
SiteDepth of the manhole and the position of the pipe
You supplySensors and transmitters certified for your zone, the logger or RTU unless EDS supplies it, site access and the asset owner’s approvals

The Sensor Fort design is patent pending. Hydraulic figures are calculated with the EDS hydraulic model. Specifications may change without notice. Full details are in the Sensor Fort datasheet.

Tell us about your sewer and your sensors.

Sensor Fort is an EDS design, patent pending. Give us the pipe diameter and grade, the flows you expect and the sensors you want to use. We’ll confirm the Sensor Fort model and the sleeves, and plan the installation with your network team.